RCBO, PME & Surge Protection Consumer Units Compared | WCED Range
WCED Range Comparison: RCBO, SPD and PME Units
Compare fitted protection, optional features and practical ordering checks. Use the comparison tables to match the functions you need to an exact product variant.
EcoHarmony buying guide · Updated 2 November 2026
Quick answer
Pick by job: RCBO + SPD units for new circuits needing surge protection, PME units for EV chargers on a PME supply without built-in protection, TPN boards for three-phase and commercial sites. Not sure? Use the Product Finder.
Single-phase PME units: what changes between the options?
These are EcoHarmony’s listed 40A RCBO/PEN configurations. Read across the row to see which optional functions are included, then open the exact variant. “No” means that feature is not selected in that catalogue configuration; it does not decide whether the installation requires it.
| Exact catalogue option | Enclosure | SPD | kWh meter | Load management |
|---|---|---|---|---|
| WPEPME08/SP | IP65 plastic | Yes | No | No |
| WPEPME12/LB | IP65 plastic | Yes | No | Yes |
| WPEPME12/LBK | IP65 plastic | Yes | Yes | No |
| WPEPME12/LBK | IP65 plastic | Yes | Yes | Yes |
| WPEPME08/C40 | IP65 plastic | No | No | No |
| WMEPME08/SP | IP40 metal | Yes | No | No |
| WMEPME10/LB | IP40 metal | Yes | No | Yes |
| WMEPME10/SP | IP40 metal | Yes | Yes | No |
| WMEPME12/LBK | IP40 metal | Yes | Yes | Yes |
| WMEPME06/C40 | IP40 metal | No | No | No |
EcoHarmony supply note: the two plastic metered configurations share WPEPME12/LBK. When the lower-specification version is unavailable, EcoHarmony supplies the higher-specification version at no extra charge. If the load-management behaviour affects your design, confirm the supplied configuration before ordering.
How the load-management option works
On EcoHarmony’s single-phase PME units with load balancing selected, load management cuts power to the charger when the property load reaches the configured limit. When the property load reduces sufficiently, the unit automatically reconnects the supply. The charger then restarts; the charging session should resume automatically, depending on the charger model and its settings. This is supply interruption and reconnection, rather than continuous adjustment of the charging current.
What is included with the selected options?
A CT clamp is included when load balancing is selected. It is not required for the other configurations. A kWh meter is fitted when the metering option is selected. Choose the functions required for your installation when selecting the variant.
For billing, remote monitoring or a particular accessory requirement, ask us to confirm the supplied meter and accessories before ordering.
Three common ordering mistakes to avoid
From EcoHarmony’s customer enquiries, the common mistakes are choosing the wrong protection for the charger, the wrong size or rating, and the wrong IP rating.
- Protection: identify the exact charger model and what it already includes, then match the installer’s required PEN, residual-current, overcurrent and surge protection.
- Size and rating: confirm the specified current rating, phase arrangement and circuit count, as well as enclosure dimensions and available mounting space. A higher amp rating is not an automatic upgrade.
- IP rating: match the enclosure to its location and exposure. An indoor unit must not be assumed suitable outdoors because it is under cover.
What you are buying—and what still needs specifying
| Feature on the order | What it adds | Check separately |
|---|---|---|
| PME/PEN protection | The assembly’s specified fault-detection and disconnection function | Charger model, supply earthing and device suitability |
| 40A RCBO | Residual-current and overcurrent protection | Curve, residual-current type, switching arrangement and circuit design |
| SPD option | A fitted surge-protection device | Required SPD type and coordination with existing protection |
| kWh meter option | Energy measurement through the monitored circuit | Exact meter model, billing suitability and any communications |
| Load-management option | The specified load-control function | CT clamp included when selected; confirm lead length and charger restart behaviour |
| Fitted enclosure | A housing with the listed fitted equipment | Mounting fixings, glands, cable entries and any remaining accessories |
Do not assume accessories, commissioning or every part needed on site are included merely because a board is described as fitted. A module count is not a count of spare ways. For a complete order, obtain the exact assembly contents and the installer’s remaining parts list.
Three differences that can change the buying decision
A kWh meter is not automatically a billing or app system
Decide whether you need a local energy reading, remote reporting or evidence suitable for charging another party. Those are different requirements. A listing that says “kWh meter” alone does not establish MID status, remote access, an app or a billing service.
Load management is not automatically smooth charging-current adjustment
On EcoHarmony’s single-phase PME units with load balancing selected, load management cuts power to the charger when the property load reaches the configured limit. When the property load reduces sufficiently, the unit automatically reconnects the supply. The charger then restarts; the charging session should resume automatically, depending on the charger model and its settings. This is supply interruption and reconnection, rather than continuous adjustment of the charging current.
Fault reset behaviour is part of the specification
WCED’s published single-phase PME information distinguishes automatic recovery after an under-voltage event from manual intervention after an over-voltage event. Check the exact supplied revision and instructions; do not apply this behaviour to every three-phase or auto-reset product. Repeated operation needs investigation, not repeated resetting.
Source: WCED PME range and manufacturer documentation. Use the model-specific instructions when planning space and operation.
Will the enclosure fit? Compare the published dimensions
| Manufacturer model | Width × height × depth | Practical implication |
|---|---|---|
| WMEPME08/SP | 232 × 240 × 112mm | Indoor metal option; allow additional space for installation and access. |
| WPEPME08/SP | 295 × 255 × 140mm | IP65 option is 63mm wider, 15mm taller and 28mm deeper than the listed metal model. |
These are WCED’s published enclosure dimensions, not our measurements. They do not include a project-specific allowance for entries, bend space, door opening or servicing. Do not extrapolate them to metered or load-management versions. Confirm the latest drawing before preparing a mounting location.
Worked buying examples
These are illustrative selection examples, not customer case studies or installation designs.
Example 1: one charger with suitable built-in PEN protection
If the installer confirms that separate PEN protection is unnecessary but specifies an RCBO and SPD, compare the RCBO + SPD family first. A PME unit is not automatically the better purchase because it contains more components. Check the charger-by-charger guide.
Example 2: one charger requiring external PEN protection outdoors
If the installation specification calls for a single-phase PEN/RCBO/SPD assembly in an IP65 enclosure, start with the IP65 PME + SPD row above. Add metering only if its capabilities serve the intended purpose; confirm load management separately if supply capacity is constrained.
Example 3: two three-phase chargers
Start with the required number of protected outgoing circuits and the site supply. Compare a multi-output assembly with separate protection for each circuit, rather than assuming two chargers can share a single-charger unit. Confirm simultaneous demand and load control before ordering.
Fitted consumer units: protection and options
Choose the supply phase first, then the required protection and installation environment. An MCB-only option provides overcurrent protection; an RCBO option adds residual-current protection. Surge protection and PEN fault protection are separate functions and should not be inferred from the presence of an RCBO.
Compare the actual named variants below: some assemblies offer 32A and 40A options, some an additional main switch, and some MCB or RCBO alternatives. Follow the selected model’s specification for the enclosure rating. An EV charger’s DC leakage detection alone does not remove the need for the required AC residual-current protection.
Choose your exact variant
Expand a product to compare its available configurations. Each link opens that exact option; current price and availability are shown on the product page.
IP65 Metal EV Consumer Unit – RCBO, MCB & Surge Protection — 4 options
IP65 Consumer Unit with RCBO + Type 2 Surge Protection — 2 options
RCBO + Surge Protection Fitted Consumer Unit (IP30 / Indoor Use) — 2 options
RCBO + Surge Protection – Fitted Consumer Unit IP40 – 3 Phase — 5 options
IP65 Weatherproof 3-Phase Consumer Unit – RCBO + Surge Protection | Outdoor EV Charger Board — 4 options
Fitted Consumer Unit Metal 2 Module IP40 White - RCBO or MCB — 4 options
WCED orders are normally dispatched the same day for next-day delivery. Availability and checkout delivery options apply; contact us for a time-critical installation.
RCBO + SPD fitted consumer units
Pre-wired units combining an RCBO (or MCB) with surge protection in one enclosure.
| Product | Fitted with | Enclosure | Rating | Phase |
|---|---|---|---|---|
| RCBO + SPD fitted consumer unit | RCBO, SPD | IP30 — indoor use | 32A or 40A | Single |
| RCBO + SPD fitted consumer unit, 3-phase | RCBO or MCB, SPD | Indoor — see the selected model’s IP rating | 32A/40A RCBO; 32A/40A/100A MCB options | Three |
| IP65 consumer unit, RCBO + Type 2 SPD | RCBO, Type 2 SPD | IP65 plastic | 32A or 40A | Single |
| IP65 3-phase consumer unit, RCBO + SPD | RCBO or MCB, SPD | IP65 plastic | 32A or 40A | Three |
PME (PEN fault) units
Where an EV charger is on a PME supply, BS 7671 Reg 722.411.4.1 requires one of the recognised protection routes. These units provide a specified PEN fault protection function. The installer must confirm the complete earthing arrangement and whether the exact unit is suitable. See What is PME in EV charging?
| Product | Fitted with | Enclosure | Rating | Phase | Chargers |
|---|---|---|---|---|---|
| 3-phase PME, 40A RCBO + surge | PME, RCBO, SPD (other options available) | IP40 metal | 40A | Three | 1 |
| Fitted consumer unit, PME + 40A RCBO | PME, RCBO (surge, kWh meter, load balancing optional) | IP40 metal | 40A | Single | 1 |
| PEN fault detection + surge protection | PME, RCBO, SPD (kWh meter, load balancing optional) | IP65 plastic | 40A | Single | 1 |
| 3-phase PEN fault unit, Tesla compatible | PME | IP40 metal | 40A | Three | Up to 6 single-phase |
A note on standards
PEN fault detection devices are not certified to one dedicated BS EN product standard the way RCBOs and SPDs are. Their use is governed by BS 7671 Reg 722.411.4.1 and related IET guidance, so check the manufacturer’s documentation for the product.
Three-phase distribution
For commercial sites, multi-charger installs and workshops. The TPN board provides the main switch and surge protection, and you add MCBs and RCBOs to suit your circuits.
| Product | What it is |
|---|---|
| 3-phase TPN distribution board | 4-pole 125A main switch, factory-fitted Type 2 SPD, ways for MCBs and RCBOs |
| 10kA MCBs for TPN boards | Individual MCBs to populate the board |
| 1-pole 10kA RCBOs for TPN boards | Individual RCBOs where per-circuit RCD protection is needed |
Heat pump and solar units
| Product | For | Fitted with |
|---|---|---|
| Heat pump consumer unit | Heat pump circuits | Type B RCD, SPD, 2-pole MCB |
| Heat pump protection unit, 20kHz Type B | Heat pumps with high-frequency inverter leakage | High-frequency Type B RCD |
| Solar PV combiner box, 1000V DC | Solar DC isolation and surge protection; one- or two-string paths | DC isolator, DC SPD |
See heat pump protection requirements and solar combiner boxes.
Enclosures and DIN modules
For jobs where you specify your own devices, the metal IP40 enclosure range covers empty cases through to factory-wired surge-protected boards. Physical DIN-rail fit does not establish electrical or assembly compatibility. Confirm the manufacturer’s permitted devices and ratings. See the IP40 enclosure range and the full WCED range.
Frequently asked questions
What is the difference between an RCBO and an RCD?
An RCD only provides earth-leakage protection and needs a separate MCB for overcurrent. An RCBO combines both. See RCBO vs MCB vs RCD.
Do I need Type A or Type B protection?
Type A covers AC and pulsating DC and is the default for most circuits. Type B is needed where equipment can produce smooth DC leakage, such as some heat pumps and EV chargers. See RCBO types explained.
Do I need surge protection?
BS 7671 requires it to be assessed on every installation, and for most modern installs the answer is yes. Units with an SPD already include it. See Do I need surge protection?
IP40 or IP65?
IP40 provides no water-ingress protection rating. IP65 provides specified dust and water-jet protection when correctly installed; suitability still depends on exposure, entries, seals and manufacturer instructions. See IP40 vs IP65.
Related guides
Not sure what your install needs?
Use the Product Finder →