WCED Product Datasheets – Technical Information for Installers
WCED reference datasheets and product-family information. Confirm the exact model, document revision and assembly contents before ordering. Product standards vary by device; a component specification does not certify the complete installation.
Compare protection functions and optional features in the WCED buying guide. Use the document revision that matches your product.
A-Type EV RCBO Kit
Plastic 2–3 way enclosure with A-type RCBO · WMEV / WME series
The WMEV family combines residual-current and overcurrent protection in a fitted enclosure. Type A describes AC and pulsating DC residual-current detection; it does not mean the device incorporates 6mA smooth-DC detection or open-PEN protection. Confirm the exact model, ratings and the charger’s additional protection requirements. Handle positions are not a substitute for electrical fault diagnosis.
What earth leakage types does the A-type RCBO detect?
What does the twin-handle system indicate about the fault type?
Are B-curve and C-curve variants both available?
What is the enclosure IP rating?
Part codes & dimensions
| Part code | Description | Dimensions W×H×D (mm) |
|---|---|---|
| WMEV206B | 2-module enclosure, 6A B-curve RCBO | 74×175×90 |
| WMEV210B | 2-module enclosure, 10A B-curve RCBO | 74×175×90 |
| WMEV216B | 2-module enclosure, 16A B-curve RCBO | 74×175×90 |
| WMEV220B | 2-module enclosure, 20A B-curve RCBO | 74×175×90 |
| WMEV225B | 2-module enclosure, 25A B-curve RCBO | 74×175×90 |
| WMEV232B | 2-module enclosure, 32A B-curve RCBO | 74×175×90 |
| WMEV240B | 2-module enclosure, 40A B-curve RCBO | 74×175×90 |
| WMEV206C | 2-module enclosure, 6A C-curve RCBO | 74×175×90 |
| WMEV210C | 2-module enclosure, 10A C-curve RCBO | 74×175×90 |
| WMEV216C | 2-module enclosure, 16A C-curve RCBO | 74×175×90 |
| WMEV220C | 2-module enclosure, 20A C-curve RCBO | 74×175×90 |
| WMEV225C | 2-module enclosure, 25A C-curve RCBO | 74×175×90 |
| WMEV232C | 2-module enclosure, 32A C-curve RCBO | 74×175×90 |
| WMEV240C | 2-module enclosure, 40A C-curve RCBO | 74×175×90 |
| WME323B-32 | 3-way enclosure, 32B RCBO + 32A MCB | 110×175×90 |
| WME32C-32 | 3-way enclosure, 32C RCBO + 32A MCB | 110×175×90 |
| WMEV332B | 3-way enclosure, 32A B-curve RCBO + blank | 110×175×90 |
| WMEV332C | 3-way enclosure, 32A C-curve RCBO + blank | 110×175×90 |
| WMEV340B | 3-way enclosure, 40A B-curve RCBO + blank | 110×175×90 |
Metal EV Protection Unit with Surge Protection
A-type RCBO + Type 2 SPD · WMRC series · 110×175×91mm
The WMRC range combines a Type A RCBO with Type 2 surge protection in a metal enclosure. Choose the current rating and trip curve required by the circuit design. Use the model drawing for dimensions and entry positions, and confirm indoor mounting conditions.
Why combine an RCBO with surge protection in one enclosure?
What surge protection level does the SPD provide?
Is the WMRC suitable for outdoor installation?
Part codes & dimensions
| Part code | Description | Dimensions W×H×D (mm) |
|---|---|---|
| WMRC32BSP | 4-way metal, A-type 32A B-curve RCBO + SPD | 110×175×91 |
| WMRC32CSP | 4-way metal, A-type 32A C-curve RCBO + SPD | 110×175×91 |
| WMRC40BSP | 4-way metal, A-type 40A B-curve RCBO + SPD | 110×175×91 |
| WMRC40CSP | 4-way metal, A-type 40A C-curve RCBO + SPD | 110×175×91 |
Plastic Weatherproof EV Protection Unit
IP65 A-type RCBO + Type 2 SPD · WPRC series · 140×205×95mm
The WPRC family offers an IP65 enclosure with the listed RCBO and surge-protection components. Confirm the selected current rating and trip curve. Type A residual-current classification does not establish integrated 6mA smooth-DC detection or PEN protection. IP65 performance depends on correct installation, entries and seals.
Does IP65 meet the requirements for an outdoor domestic EV charger installation?
What cable entry options are available on the WPRC enclosure?
Can the WPRC be used with three-phase EV chargers?
Part codes & dimensions
| Part code | Description | Dimensions W×H×D (mm) |
|---|---|---|
| WPRC32BSP | IP65 A-type 32A B-curve RCBO + SPD | 140×205×95 |
| WPRC32CSP | IP65 A-type 32A C-curve RCBO + SPD | 140×205×95 |
| WPRC40BSP | IP65 A-type 40A B-curve RCBO + SPD | 140×205×95 |
| WPRC40CSP | IP65 A-type 40A C-curve RCBO + SPD | 140×205×95 |
Metal Weatherproof IP65 EV Protection Unit
IP65 aluminium enclosure, A-type RCBO + Type 2 SPD · WMIP series · 164×232×102mm
The WMIP range offers metal IP65 enclosures and fitted RCBO/SPD configurations. Choose the exact assembly and confirm its dimensions, mounting conditions and cable-entry requirements in the manufacturer documentation. IP65 performance depends on suitable entries, seals and installation.
Why choose metal (WMIP) over plastic (WPRC) for outdoor installations?
What is the recommended torque for terminal connections?
Is the WMIP5 enclosure available without pre-fitted protection devices?
Part codes & dimensions
| Part code | Description | Dimensions W×H×D (mm) |
|---|---|---|
| WMIP5 | 5-module IP65 grey metal enclosure (empty) | 164×232×102 |
| WMIP5-W | 5-module IP65 white metal enclosure (empty) | 164×232×102 |
| WMIP32BSP | 32A B-curve RCBO + SPD | 164×232×102 |
| WMIP32CSP | 32A C-curve RCBO + SPD | 164×232×102 |
| WMIP40BSP | 40A B-curve RCBO + SPD | 164×232×102 |
| WMIP40CSP | 40A C-curve RCBO + SPD | 164×232×102 |
Weatherproof IP65 B-Type EV Kit
IP65 B-type RCD + MCB · WPEVKIT series · 140×205×95mm
The WPEVKIT family combines a Type B RCD and MCB in a plastic IP65 enclosure. It is a product family to consider where the circuit design specifies those functions. Confirm current ratings, poles and the complete charger protection requirements before ordering.
When should a B-type RCD be used instead of an A-type RCBO?
Can the WPEVKIT63 be used with both 7kW and 22kW chargers?
Part codes & dimensions
| Part code | Description | Dimensions W×H×D (mm) |
|---|---|---|
| WPEVKIT63-EC | IP65 B-type 63A RCD + 40A C-curve MCB | 140×205×95 |
EV Kit — Metal Enclosure
B-type RCD + MCB · WEVKIT series · 110×175×91mm
The WEVKIT63 combines a Type B RCD and MCB in a metal enclosure. Select it for a suitable indoor location and a circuit requiring the specified protection. A sheltered outdoor position must not be treated as equivalent to indoor use.
What is the difference between WEVKIT63 and WPEVKIT63-EC?
Part codes & dimensions
| Part code | Description | Dimensions W×H×D (mm) |
|---|---|---|
| WEVKIT63 | B-type 63A RCD + 40A C-curve MCB | 110×175×91 |
EV Connection Units
100A main switch + MCB isolation units · WEVCU / WERM / WSRC series · 110×175×91mm
EV connection units provide isolation and overload protection for EV sockets without a built-in isolator. The 100A main switch provides safe isolation of the charger circuit for servicing or in an emergency. The MCB provides overload and short-circuit protection. WSRC variants add kWh metering for energy monitoring. SPD variants (WEVCU32BSP, WSRC532BSP) include Type 2 surge protection. WPEVCU32BSP is the IP65 weatherproof version for outdoor socket installations.
Why is a 100A main switch specified rather than a lower rating?
Can other MCB ratings be fitted instead of 32A?
Does the WSRC532BSP include kWh metering?
Part codes & dimensions
| Part code | Description | Dimensions W×H×D (mm) |
|---|---|---|
| WEVCU | 100A main switch + 32A MCB | 110×175×91 |
| WEVCU32B | 100A main switch + 32A B-curve MCB | 110×175×91 |
| WEVCU40B | 100A main switch + 40A B-curve MCB | 110×175×91 |
| WERM6332 | 63A A-type RCD + 32A MCB | 110×175×91 |
| WEVCU32BSP | 100A main switch + 32A B MCB + SPD | 175×110×91 |
| WSRC532BSP | 100A main switch + 32A B MCB + SPD + kWh meter | 175×110×91 |
| WPEVCU32BSP | 100A main switch + 32A B MCB + SPD — IP65 8-way enclosure | 212×205×95 |
WTPN 125A Three-Phase Distribution Board
TP&N distribution board with 125A 4-pole main switch + Type 2 SPD · WTPN series
The WTPN range is a robust 1.2mm steel three-phase distribution board for commercial, industrial, and high-demand domestic EV charging installations. Each board is supplied with a 125A 4-pole main switch and a Type 2 surge protection device (SPD) as standard. Solid copper busbar construction ensures low impedance connections. Backed-out terminal screws, keyway mounting points, and separate metal gland plates simplify installation and inspection. Extension boards (WTPNEB14) and spreader boxes (WTPNSB) allow the system to be expanded without replacing the primary enclosure.
What DIN rail devices are compatible with the WTPN board?
Can the WTPN be used for a multi-bay EV charging installation?
Is a TPN to single-phase converter kit available?
Part codes & dimensions
| Part code | Description | Dimensions W×H×D (mm) |
|---|---|---|
| WTPN04-125 | 4-way TP&N board, 125A 4-pole main switch + Type 2 SPD; outgoing devices ordered separately | 460×505×120 |
| WTPN06-125 | 6-way TP&N board | 460×559×120 |
| WTPN08-125 | 8-way TP&N board | 460×613×120 |
| WTPN12-125 | 12-way TP&N board | 460×613×120 |
| WTPN16-125 | 16-way TP&N board | 460×829×120 |
| WTPN24-125 | 24-way TP&N board | 460×1045×120 |
| WTPNEB14 | TPN extension board, 14 modules | 460×341×120 |
| WTPNSB | TPN spreader box | 460×433×97 |
A-Type RCBO — DIN Rail
10kA single-module A-type RCBO · WRT series · 17.8×116×76mm
The WRT family combines residual-current and overcurrent protection in a compact RCBO. Select the current rating, trip curve, residual-current characteristics and permitted assembly combination from the exact model documentation.
Are these RCBOs suitable for use in solar PV installations?
What breaking capacity do the WRT RCBOs offer?
Part codes & dimensions
| Part code | Description | Dimensions W×H×D (mm) |
|---|---|---|
| WRT106B-030 | A-type 6A B-curve, high immunity, 30mA | 17.8×116×76 |
| WRT110B-030 | A-type 10A B-curve, high immunity, 30mA | 17.8×116×76 |
| WRT116B-030 | A-type 16A B-curve, high immunity, 30mA | 17.8×116×76 |
| WRT120B-030 | A-type 20A B-curve, high immunity, 30mA | 17.8×116×76 |
| WRT132B-030 | A-type 32A B-curve, high immunity, 30mA | 17.8×116×76 |
| WRT140B-030 | A-type 40A B-curve, high immunity, 30mA | 17.8×116×76 |
| WRT106C-030 | A-type 6A C-curve, high immunity, 30mA | 17.8×116×76 |
| WRT110C-030 | A-type 10A C-curve, high immunity, 30mA | 17.8×116×76 |
| WRT116C-030 | A-type 16A C-curve, high immunity, 30mA | 17.8×116×76 |
| WRT120C-030 | A-type 20A C-curve, high immunity, 30mA | 17.8×116×76 |
| WRT132C-030 | A-type 32A C-curve, high immunity, 30mA | 17.8×116×76 |
| WRT140C-030 | A-type 40A C-curve, high immunity, 30mA | 17.8×116×76 |
Three-Phase SPD Units
8-way IP40 metal enclosure, 4-pole Type 2 SPD + 4-pole MCB or RCBO · WMCUSP4 / WRCUSP4 series
The WMCUSP4 and WRCUSP4 units provide three-phase surge protection at the point of connection for commercial EV chargers and other three-phase loads. Each consists of an 8-way IP40 metal enclosure with a 4-pole 20kA/40kA Type 2 surge protector. The WMCUSP4 includes a 4-pole 10kA MCB; the WRCUSP4 replaces this with a 4-pole A-type RCBO for installations also requiring three-phase earth leakage protection.
What is the difference between WMCUSP4 and WRCUSP4?
At what point in the installation should the SPD unit be fitted?
Part codes
| Part code | Description |
|---|---|
| WMCUSP4*** | 8-way IP40 metal, 4-pole Type 2 SPD + 4-pole MCB (*** = amperage and curve) |
| WRCUSP4*** | 8-way IP40 metal, 4-pole Type 2 SPD + 4-pole A-type RCBO (*** = amperage and curve) |
PME Fault Detection Units
Three-phase PME relay with automatic isolation · WARB / WMTP series
The WARB and WMTP families provide open-PEN fault detection and switching functions in specified assemblies. Select the unit for the supply, output arrangement and number of protected circuits. Use the exact model’s instructions for detection limits, switching, reset behaviour and commissioning.
Does fitting a PME protection unit mean I no longer need an earth rod?
Does the unit work on both 400V and 415V supplies?
Why does an over-voltage trip require a manual reset but an under-voltage resets automatically?
What is the WMTP multi-point unit and when is it used?
Is this product compliant with Amendment 2 of BS 7671?
Part codes & dimensions
| Part code | Description | Dimensions W×H×D (mm) |
|---|---|---|
| WARB5100C/PME | 100A MCB + PME relay | — |
| WARB5100C/PMESP | 100A MCB + PME relay + SPD | — |
| WARB5100C/PME40R | 100A MCB + PME relay + 40A RCBO | — |
| WARB5100C/PME40RSP | 100A MCB + PME relay + 40A RCBO + SPD | — |
| WMTP28-R40CSP | 2× RCBO + 1× PME detector | 500×304×112 |
| WMTP36-R40CSP | 3× RCBO + 2× PME detector | 500×530×112 |
Three-Phase Weatherproof Fused Switch
IP weatherproof 3-phase isolation switch · WTFS series
The WTFS range provides three-phase isolation and fused protection in a single weatherproof enclosure, suitable for outdoor disconnection of three-phase EV chargers, heat pumps, and other three-phase equipment. Available in 32A, 63A, 80A, and 100A ratings to suit a range of three-phase load currents.
Is the WTFS suitable for use as a means of isolation for a 22kW EV charger?
Part codes
| Part code | Description |
|---|---|
| WTFS32 | 32A 3-phase weatherproof fused switch |
| WTFS63 | 63A 3-phase weatherproof fused switch |
| WTFS80 | 80A 3-phase weatherproof fused switch |
| WTFS100 | 100A 3-phase weatherproof fused switch |
Enquire about a product
Can't find what you need, or want to discuss your installation requirements? Fill in the form below and a member of the team will get back to you.
Frequently asked questions — WCED electrical protection
What is PME protection, and why do I need it for EV charger installations?
Do all EV charger installations on a PME supply require PME protection?
What is the difference between A-type and B-type RCD/RCBO protection?
What is the difference between B-curve and C-curve MCBs and RCBOs?
How do surge protection devices (SPDs) protect EV chargers?
Can I install WCED products myself, or do I need a qualified electrician?
How often should WCED protection devices be tested?
Are WCED products compliant with UK wiring regulations?
Explore Our Guides
A different set of guides each time you visit — covering troubleshooting, buying advice, technical explainers, and more.