WCED Product Datasheets – Technical Information for Installers

WCED reference datasheets and product-family information. Confirm the exact model, document revision and assembly contents before ordering. Product standards vary by device; a component specification does not certify the complete installation.

Compare protection functions and optional features in the WCED buying guide. Use the document revision that matches your product.

A-Type EV RCBO Kit

Plastic 2–3 way enclosure with A-type RCBO · WMEV / WME series

The WMEV family combines residual-current and overcurrent protection in a fitted enclosure. Type A describes AC and pulsating DC residual-current detection; it does not mean the device incorporates 6mA smooth-DC detection or open-PEN protection. Confirm the exact model, ratings and the charger’s additional protection requirements. Handle positions are not a substitute for electrical fault diagnosis.

What earth leakage types does the A-type RCBO detect?
A Type A RCBO detects AC and pulsating DC residual currents. It does not by itself provide open-PEN protection or establish that a separate earthing measure is unnecessary. Check the EV charger’s DC residual-current provision and the complete installation requirements separately.
What does the twin-handle system indicate about the fault type?
Use the exact RCBO’s operating instructions to interpret its indicators and handle positions. They can assist investigation, but do not establish the cause of a trip on their own. Repeated tripping should be investigated by the installer.
Are B-curve and C-curve variants both available?
Yes. Both B-curve (general domestic/light commercial) and C-curve (higher inrush applications) are available across 6A, 10A, 16A, 20A, 25A, 32A, and 40A ratings. The 3-way enclosure options also include a combined RCBO + MCB configuration for dual-circuit protection.
What is the enclosure IP rating?
Confirm the exact enclosure’s IP rating and permitted mounting conditions. An enclosure with no water-ingress rating must not be assumed suitable outdoors merely because a roof shelters it. Compare IP65 options where the installation specification requires them.
Part code Description Dimensions W×H×D (mm)
WMEV206B 2-module enclosure, 6A B-curve RCBO 74×175×90
WMEV210B 2-module enclosure, 10A B-curve RCBO 74×175×90
WMEV216B 2-module enclosure, 16A B-curve RCBO 74×175×90
WMEV220B 2-module enclosure, 20A B-curve RCBO 74×175×90
WMEV225B 2-module enclosure, 25A B-curve RCBO 74×175×90
WMEV232B 2-module enclosure, 32A B-curve RCBO 74×175×90
WMEV240B 2-module enclosure, 40A B-curve RCBO 74×175×90
WMEV206C 2-module enclosure, 6A C-curve RCBO 74×175×90
WMEV210C 2-module enclosure, 10A C-curve RCBO 74×175×90
WMEV216C 2-module enclosure, 16A C-curve RCBO 74×175×90
WMEV220C 2-module enclosure, 20A C-curve RCBO 74×175×90
WMEV225C 2-module enclosure, 25A C-curve RCBO 74×175×90
WMEV232C 2-module enclosure, 32A C-curve RCBO 74×175×90
WMEV240C 2-module enclosure, 40A C-curve RCBO 74×175×90
WME323B-32 3-way enclosure, 32B RCBO + 32A MCB 110×175×90
WME32C-32 3-way enclosure, 32C RCBO + 32A MCB 110×175×90
WMEV332B 3-way enclosure, 32A B-curve RCBO + blank 110×175×90
WMEV332C 3-way enclosure, 32A C-curve RCBO + blank 110×175×90
WMEV340B 3-way enclosure, 40A B-curve RCBO + blank 110×175×90
Download datasheet (PDF)

Metal EV Protection Unit with Surge Protection

A-type RCBO + Type 2 SPD · WMRC series · 110×175×91mm

The WMRC range combines a Type A RCBO with Type 2 surge protection in a metal enclosure. Choose the current rating and trip curve required by the circuit design. Use the model drawing for dimensions and entry positions, and confirm indoor mounting conditions.

Why combine an RCBO with surge protection in one enclosure?
Fitting surge protection at the point of EV charger connection protects the charger's electronics from voltage transients caused by lightning strikes, grid switching events, and nearby inductive loads. Combining the SPD with the RCBO in a single enclosure saves DIN rail space, simplifies installation, and reduces the number of separate products to specify and stock.
What surge protection level does the SPD provide?
The WMRC units include a Type 2 SPD rated at 20kA/40kA surge current. Type 2 SPDs are designed for installation at the distribution board or point-of-use, providing protection against indirect lightning strikes and switching transients in accordance with BS EN 61643-11 and the requirements of BS 7671 Amendment 2.
Is the WMRC suitable for outdoor installation?
Treat the listed indoor WMRC units as indoor equipment. A powder-coated metal case is not evidence of outdoor suitability. Select the exact enclosure using its documented IP rating, environmental limits and installation instructions.
Part code Description Dimensions W×H×D (mm)
WMRC32BSP 4-way metal, A-type 32A B-curve RCBO + SPD 110×175×91
WMRC32CSP 4-way metal, A-type 32A C-curve RCBO + SPD 110×175×91
WMRC40BSP 4-way metal, A-type 40A B-curve RCBO + SPD 110×175×91
WMRC40CSP 4-way metal, A-type 40A C-curve RCBO + SPD 110×175×91
Download datasheet (PDF)
Shop this range

Plastic Weatherproof EV Protection Unit

IP65 A-type RCBO + Type 2 SPD · WPRC series · 140×205×95mm

The WPRC family offers an IP65 enclosure with the listed RCBO and surge-protection components. Confirm the selected current rating and trip curve. Type A residual-current classification does not establish integrated 6mA smooth-DC detection or PEN protection. IP65 performance depends on correct installation, entries and seals.

Does IP65 meet the requirements for an outdoor domestic EV charger installation?
IP65 is not a universal minimum for every outdoor electrical installation. Select the enclosure for the actual external influences and manufacturer instructions. Check exposure, condensation, glands, seals, temperature and maintenance access as well as the IP code.
What cable entry options are available on the WPRC enclosure?
The WPRC enclosure includes circular knock-outs on the top and bottom panels. These accept standard M20 cable glands, which can be enlarged to M32 on site. Maintaining the IP65 rating requires appropriate cable glands to be fitted once cables are routed.
Can the WPRC be used with three-phase EV chargers?
The WPRC range is a single-phase product. For three-phase EV charger installations (11kW–22kW), the WMTP or WTPN distribution board ranges should be specified instead.
Part code Description Dimensions W×H×D (mm)
WPRC32BSP IP65 A-type 32A B-curve RCBO + SPD 140×205×95
WPRC32CSP IP65 A-type 32A C-curve RCBO + SPD 140×205×95
WPRC40BSP IP65 A-type 40A B-curve RCBO + SPD 140×205×95
WPRC40CSP IP65 A-type 40A C-curve RCBO + SPD 140×205×95
Download datasheet (PDF)
Shop this range

Metal Weatherproof IP65 EV Protection Unit

IP65 aluminium enclosure, A-type RCBO + Type 2 SPD · WMIP series · 164×232×102mm

The WMIP range offers metal IP65 enclosures and fitted RCBO/SPD configurations. Choose the exact assembly and confirm its dimensions, mounting conditions and cable-entry requirements in the manufacturer documentation. IP65 performance depends on suitable entries, seals and installation.

Why choose metal (WMIP) over plastic (WPRC) for outdoor installations?
Compare the exact models’ material, impact rating, mounting space and environmental limits. IP65 describes ingress protection; it does not establish impact resistance or suitability for every outdoor location.
What is the recommended torque for terminal connections?
Use the torque specified for each terminal in the exact assembly’s instructions. Different devices and connections may require different values; do not apply one figure to every terminal.
Is the WMIP5 enclosure available without pre-fitted protection devices?
WMIP5 and WMIP5-W are empty enclosure options. Choose the required colour and confirm the manufacturer’s permitted device combinations. Physical DIN-rail fit alone does not establish assembly compatibility.
Part code Description Dimensions W×H×D (mm)
WMIP5 5-module IP65 grey metal enclosure (empty) 164×232×102
WMIP5-W 5-module IP65 white metal enclosure (empty) 164×232×102
WMIP32BSP 32A B-curve RCBO + SPD 164×232×102
WMIP32CSP 32A C-curve RCBO + SPD 164×232×102
WMIP40BSP 40A B-curve RCBO + SPD 164×232×102
WMIP40CSP 40A C-curve RCBO + SPD 164×232×102
Download datasheet (PDF)

Weatherproof IP65 B-Type EV Kit

IP65 B-type RCD + MCB · WPEVKIT series · 140×205×95mm

The WPEVKIT family combines a Type B RCD and MCB in a plastic IP65 enclosure. It is a product family to consider where the circuit design specifies those functions. Confirm current ratings, poles and the complete charger protection requirements before ordering.

When should a B-type RCD be used instead of an A-type RCBO?
For Mode 3 EV charging, the required RCD arrangement depends on the charger’s DC residual-current protection and applicable installation requirements. A Type B RCD is one route; suitable Type A or Type F protection with the required RDC-DD is another. Check the exact charger instructions and complete design.
Can the WPEVKIT63 be used with both 7kW and 22kW chargers?
The WPEVKIT63-EC is a single-phase assembly. A three-phase charger needs a suitable three-phase circuit and protection arrangement. Charging power alone is not enough to select a kit.
Part code Description Dimensions W×H×D (mm)
WPEVKIT63-EC IP65 B-type 63A RCD + 40A C-curve MCB 140×205×95
Download datasheet (PDF)

EV Kit — Metal Enclosure

B-type RCD + MCB · WEVKIT series · 110×175×91mm

The WEVKIT63 combines a Type B RCD and MCB in a metal enclosure. Select it for a suitable indoor location and a circuit requiring the specified protection. A sheltered outdoor position must not be treated as equivalent to indoor use.

What is the difference between WEVKIT63 and WPEVKIT63-EC?
The principal distinction is the enclosure: WEVKIT63 is the indoor metal option and WPEVKIT63-EC the plastic IP65 option. Verify the fitted devices and installation conditions for the exact model before treating them as equivalent.
Part code Description Dimensions W×H×D (mm)
WEVKIT63 B-type 63A RCD + 40A C-curve MCB 110×175×91
Download datasheet (PDF)

EV Connection Units

100A main switch + MCB isolation units · WEVCU / WERM / WSRC series · 110×175×91mm

EV connection units provide isolation and overload protection for EV sockets without a built-in isolator. The 100A main switch provides safe isolation of the charger circuit for servicing or in an emergency. The MCB provides overload and short-circuit protection. WSRC variants add kWh metering for energy monitoring. SPD variants (WEVCU32BSP, WSRC532BSP) include Type 2 surge protection. WPEVCU32BSP is the IP65 weatherproof version for outdoor socket installations.

Why is a 100A main switch specified rather than a lower rating?
The switch rating describes the device under its specified operating conditions. It does not set the charger’s circuit rating or increase the incoming supply capacity. The complete assembly, protective devices and installation design determine the permitted load.
Can other MCB ratings be fitted instead of 32A?
Yes. The standard catalogue includes 32A and 40A MCB ratings. Other ratings are available to order — contact us with your specific requirement.
Does the WSRC532BSP include kWh metering?
Yes. The WSRC532BSP includes a 100A main switch, 32A B-curve MCB, Type 2 SPD, and a kWh meter. Confirm that this component schedule meets the circuit requirements.
Part code Description Dimensions W×H×D (mm)
WEVCU 100A main switch + 32A MCB 110×175×91
WEVCU32B 100A main switch + 32A B-curve MCB 110×175×91
WEVCU40B 100A main switch + 40A B-curve MCB 110×175×91
WERM6332 63A A-type RCD + 32A MCB 110×175×91
WEVCU32BSP 100A main switch + 32A B MCB + SPD 175×110×91
WSRC532BSP 100A main switch + 32A B MCB + SPD + kWh meter 175×110×91
WPEVCU32BSP 100A main switch + 32A B MCB + SPD — IP65 8-way enclosure 212×205×95
Download datasheet (PDF)

WTPN 125A Three-Phase Distribution Board

TP&N distribution board with 125A 4-pole main switch + Type 2 SPD · WTPN series

The WTPN range is a robust 1.2mm steel three-phase distribution board for commercial, industrial, and high-demand domestic EV charging installations. Each board is supplied with a 125A 4-pole main switch and a Type 2 surge protection device (SPD) as standard. Solid copper busbar construction ensures low impedance connections. Backed-out terminal screws, keyway mounting points, and separate metal gland plates simplify installation and inspection. Extension boards (WTPNEB14) and spreader boxes (WTPNSB) allow the system to be expanded without replacing the primary enclosure.

What DIN rail devices are compatible with the WTPN board?
Use outgoing devices specifically permitted for the exact WTPN board. EcoHarmony offers dedicated TPN RCBOs and TPN MCBs. Neither a common brand nor physical DIN-rail fit establishes compatibility.
Can the WTPN be used for a multi-bay EV charging installation?
A suitable TPN board can distribute power to several EV circuits. Create a circuit schedule and confirm usable capacity, device widths, phase loading and supply demand. Board way count alone does not determine the number of chargers it can support.
Is a TPN to single-phase converter kit available?
A TPN board can supply suitably designed single-phase outgoing circuits from a three-phase supply. That is different from configuring the board for a single-phase incoming supply. Ask for the exact board’s approved arrangement and any required conversion accessory.
Part code Description Dimensions W×H×D (mm)
WTPN04-125 4-way TP&N board, 125A 4-pole main switch + Type 2 SPD; outgoing devices ordered separately 460×505×120
WTPN06-125 6-way TP&N board 460×559×120
WTPN08-125 8-way TP&N board 460×613×120
WTPN12-125 12-way TP&N board 460×613×120
WTPN16-125 16-way TP&N board 460×829×120
WTPN24-125 24-way TP&N board 460×1045×120
WTPNEB14 TPN extension board, 14 modules 460×341×120
WTPNSB TPN spreader box 460×433×97
Download datasheet (PDF)
Shop this range

A-Type RCBO — DIN Rail

10kA single-module A-type RCBO · WRT series · 17.8×116×76mm

The WRT family combines residual-current and overcurrent protection in a compact RCBO. Select the current rating, trip curve, residual-current characteristics and permitted assembly combination from the exact model documentation.

Are these RCBOs suitable for use in solar PV installations?
For a generation circuit, verify bidirectional suitability for the exact RCBO part number, as well as the inverter’s residual-current requirements and the assembly design. Do not infer this from the WRT family name alone.
What breaking capacity do the WRT RCBOs offer?
The listed WRT RCBOs have a 10kA breaking capacity. The installer must check this against the installation’s prospective fault current and any manufacturer-specified coordination requirements.
Part code Description Dimensions W×H×D (mm)
WRT106B-030 A-type 6A B-curve, high immunity, 30mA 17.8×116×76
WRT110B-030 A-type 10A B-curve, high immunity, 30mA 17.8×116×76
WRT116B-030 A-type 16A B-curve, high immunity, 30mA 17.8×116×76
WRT120B-030 A-type 20A B-curve, high immunity, 30mA 17.8×116×76
WRT132B-030 A-type 32A B-curve, high immunity, 30mA 17.8×116×76
WRT140B-030 A-type 40A B-curve, high immunity, 30mA 17.8×116×76
WRT106C-030 A-type 6A C-curve, high immunity, 30mA 17.8×116×76
WRT110C-030 A-type 10A C-curve, high immunity, 30mA 17.8×116×76
WRT116C-030 A-type 16A C-curve, high immunity, 30mA 17.8×116×76
WRT120C-030 A-type 20A C-curve, high immunity, 30mA 17.8×116×76
WRT132C-030 A-type 32A C-curve, high immunity, 30mA 17.8×116×76
WRT140C-030 A-type 40A C-curve, high immunity, 30mA 17.8×116×76
Download datasheet (PDF)
Shop this range

Three-Phase SPD Units

8-way IP40 metal enclosure, 4-pole Type 2 SPD + 4-pole MCB or RCBO · WMCUSP4 / WRCUSP4 series

The WMCUSP4 and WRCUSP4 units provide three-phase surge protection at the point of connection for commercial EV chargers and other three-phase loads. Each consists of an 8-way IP40 metal enclosure with a 4-pole 20kA/40kA Type 2 surge protector. The WMCUSP4 includes a 4-pole 10kA MCB; the WRCUSP4 replaces this with a 4-pole A-type RCBO for installations also requiring three-phase earth leakage protection.

What is the difference between WMCUSP4 and WRCUSP4?
Both are 8-way IP40 metal enclosures with a 4-pole Type 2 SPD. The WMCUSP4 includes a 4-pole MCB (overload and short-circuit protection only). The WRCUSP4 includes a 4-pole A-type RCBO, adding earth leakage protection — suitable for installations where the EV charger or equipment being protected does not include integral RCD protection.
At what point in the installation should the SPD unit be fitted?
SPD location and coordination depend on the installation design, existing surge protection, circuit distance and the equipment. An SPD at the main incomer is not automatically Type 1, and a second SPD at the equipment is not automatically required. Use the exact SPD instructions and installation assessment.
Part code Description
WMCUSP4*** 8-way IP40 metal, 4-pole Type 2 SPD + 4-pole MCB (*** = amperage and curve)
WRCUSP4*** 8-way IP40 metal, 4-pole Type 2 SPD + 4-pole A-type RCBO (*** = amperage and curve)
Download datasheet (PDF)
Shop this range

PME Fault Detection Units

Three-phase PME relay with automatic isolation · WARB / WMTP series

The WARB and WMTP families provide open-PEN fault detection and switching functions in specified assemblies. Select the unit for the supply, output arrangement and number of protected circuits. Use the exact model’s instructions for detection limits, switching, reset behaviour and commissioning.

Does fitting a PME protection unit mean I no longer need an earth rod?
An appropriate PEN fault protection arrangement can support an EV installation without a separate electrode for that purpose. Confirm the exact device and complete design. The device may disconnect the charger’s live conductors and protective earth; do not describe it as switching the incoming network PEN conductor.
Does the unit work on both 400V and 415V supplies?
Check the supply voltage and operating limits in the exact model’s datasheet. Do not assume one set of thresholds or configuration instructions applies to every WARB and WMTP assembly.
Why does an over-voltage trip require a manual reset but an under-voltage resets automatically?
Reset behaviour is model-specific. Follow the unit’s fault and reset instructions, and have a persistent or unexplained supply fault investigated. Do not assume an automatic restart proves that the underlying fault has been resolved.
What is the WMTP multi-point unit and when is it used?
The WMTP28 and WMTP36 are enclosures that combine a PME relay with two or three individually protected RCBO circuits respectively — suitable for small multi-bay EV charging installations where each charger needs its own RCBO protection but a single PME relay monitors the supply for all of them. This reduces panel space and wiring compared to fitting separate units.
Is this product compliant with Amendment 2 of BS 7671?
Use the manufacturer’s declaration and model-specific instructions to establish the device’s intended protection arrangement. A suitable assembly may disconnect the charger’s live conductors and protective earth; it does not switch the incoming network PEN conductor. The installer confirms the complete installation design.
Part code Description Dimensions W×H×D (mm)
WARB5100C/PME 100A MCB + PME relay —
WARB5100C/PMESP 100A MCB + PME relay + SPD —
WARB5100C/PME40R 100A MCB + PME relay + 40A RCBO —
WARB5100C/PME40RSP 100A MCB + PME relay + 40A RCBO + SPD —
WMTP28-R40CSP 2× RCBO + 1× PME detector 500×304×112
WMTP36-R40CSP 3× RCBO + 2× PME detector 500×530×112
Download datasheet (PDF)

Three-Phase Weatherproof Fused Switch

IP weatherproof 3-phase isolation switch · WTFS series

The WTFS range provides three-phase isolation and fused protection in a single weatherproof enclosure, suitable for outdoor disconnection of three-phase EV chargers, heat pumps, and other three-phase equipment. Available in 32A, 63A, 80A, and 100A ratings to suit a range of three-phase load currents.

Is the WTFS suitable for use as a means of isolation for a 22kW EV charger?
A nominal 22kW three-phase charger draws approximately 32A per phase. Select the fused switch from the charger instructions, load duty, fuse arrangement and installation conditions. The power figure alone does not establish the correct switch or fuse rating.
Part code Description
WTFS32 32A 3-phase weatherproof fused switch
WTFS63 63A 3-phase weatherproof fused switch
WTFS80 80A 3-phase weatherproof fused switch
WTFS100 100A 3-phase weatherproof fused switch
Download datasheet (PDF)

Enquire about a product

Can't find what you need, or want to discuss your installation requirements? Fill in the form below and a member of the team will get back to you.

Frequently asked questions — WCED electrical protection

What is PME protection, and why do I need it for EV charger installations?
PME means Protective Multiple Earthing. A broken supply PEN conductor can cause dangerous voltages on connected exposed metalwork. An appropriate open-PEN protection arrangement addresses that risk for the EV installation. Its operation and conductor switching depend on the exact device and design; it must not be described as disconnecting the incoming network PEN conductor.
Do all EV charger installations on a PME supply require PME protection?
EV charging on a PME supply requires the designer to assess the applicable earthing and open-PEN protection provisions. There are multiple permitted arrangements, each with conditions. A conventional RCBO or SPD alone does not provide open-PEN protection. Use the current wiring requirements and exact manufacturer instructions rather than treating an earth rod and a PME unit as universally interchangeable.
What is the difference between A-type and B-type RCD/RCBO protection?
Type A detects AC and pulsating DC residual currents; Type B additionally detects smooth DC and specified frequency components. EV charging also requires consideration of DC detection, individual charging-point protection and upstream devices. Use the exact charger instructions and the charger protection guide.
What is the difference between B-curve and C-curve MCBs and RCBOs?
B and C curves describe instantaneous overcurrent operation, not residual-current type. Select the curve using the equipment instructions and circuit design, including fault-disconnection requirements. A C curve is not a general upgrade for unwanted tripping.
How do surge protection devices (SPDs) protect EV chargers?
SPDs limit transient overvoltage. Type, location, connection arrangement and coordination must suit the installation. They do not replace overload, residual-current or open-PEN protection, and do not guarantee that equipment cannot be damaged. See the SPD selection guide.
Can I install WCED products myself, or do I need a qualified electrician?
Have a competent electrical installer design, install and verify the protection assembly. The installer should also establish the certification and notification requirements that apply to the work and location.
How often should WCED protection devices be tested?
Follow the manufacturer’s test-button instructions and maintenance interval for the exact device. The installation’s periodic inspection interval should be set by the responsible electrical professional, considering its use and condition. A test-button check does not replace inspection and electrical testing.
Are WCED products compliant with UK wiring regulations?
Check the manufacturer’s declaration and applicable product standards for the exact model. Wiring requirements apply to the complete installation; no single product statement establishes compliance for every proposed installation.