The 3 Phase PME MCB allows 3 phase PME protection to be added to any cabinet build or EV installation. Provides open-PEN fault monitoring within the listed assembly. Use the variant specification to identify the included circuit protection and metering or load-management options.
WCED multi-circuit protection assemblies for installations supplied from a three-phase system. Provides open-PEN fault monitoring within the listed assembly. Use the variant specification to identify the included circuit protection and metering or load-management options.
A WCED three-phase open-PEN protection assembly with a choice of protective devices and surge-protection options. Provides open-PEN fault monitoring within the listed assembly. Use the variant specification to identify the included circuit protection and metering or load-management options.
WCED three-phase and neutral distribution boards with a four-pole 125A main switch and Type 2 surge protection. A TPN board distributes a three-phase supply to outgoing circuits. Choose the board size for the circuit schedule, or select an extension or spreader box accessory below.
This WCED single-phase metal consumer unit combines PME/PEN fault detection and a 40A RCBO in an IP40 enclosure for dry indoor locations. Provides open-PEN fault monitoring within the listed assembly. Use the variant specification to identify the included circuit protection and metering or load-management options.
Fitted Consumer Unit Metal 2 Module White with DIN rail, IP40 for Indoor Application A fitted unit brings the listed electrical devices together in one enclosure. Compare the included components and enclosure rating before choosing a variant.
Fitted heat pump consumer unit with high-frequency Type B residual-current protection and outgoing devices for heat pump, control and immersion circuits. Brings the listed protection and switching devices together in an enclosure for the heat pump supply and associated circuits. Match the outgoing devices to the heat pump requirements.
Fitted heat pump consumer unit with Type B RCD, surge protection and selectable outgoing circuit protection. Brings the listed protection and switching devices together in an enclosure for the heat pump supply and associated circuits. Match the outgoing devices to the heat pump requirements.
This pre-fitted single-phase consumer unit comes ready-wired with an RCBO and Type 2 surge protection device, designed for straightforward EV charger installations where all the protection components need to be in a single, neat enclosure. A fitted unit brings the listed electrical devices together in one enclosure. Compare the included components and enclosure rating before choosing a variant.
Metal IP65 consumer unit with selectable circuit-protection and surge-protection configurations for EV installations. A fitted unit brings the listed electrical devices together in one enclosure. Compare the included components and enclosure rating before choosing a variant.
This IP65 weatherproof 3-phase consumer unit is a pre-fitted, ready-to-wire board designed for outdoor EV charger installations on three-phase supplies. A fitted unit brings the listed electrical devices together in one enclosure. Compare the included components and enclosure rating before choosing a variant.
Indoor metal enclosures and consumer units, with empty, main-switch, surge-protection and twin-RCD configurations. Provides space to house the selected electrical devices. Check enclosure size and the components included with each configuration.
DIN-rail modular contactor for switching electrical loads. Select the required current rating, pole arrangement and control voltage. A control signal operates the contacts, allowing equipment such as heating, lighting or charging circuits to be switched remotely.
This product is used in Ecoharmony products that use Supply Optimisation and Load Curtailment. It measures current in the monitored supply cable so compatible control equipment can respond to changing electrical demand.
WAR Series Type A RCDs provide reliable residual current protection for indoor consumer units, workshops, and EV charging circuits. An RCD monitors residual current and disconnects the circuit when its operating conditions are met. Select the required residual-current type, sensitivity, current rating and pole arrangement.
Single-module AFDD/RCBO combining arc-fault detection, residual-current protection and overcurrent protection. An RCD monitors residual current and disconnects the circuit when its operating conditions are met. Select the required residual-current type, sensitivity, current rating and pole arrangement.
WAR Series Time-Delay Type A RCDs (100 mA) deliver reliable earth leakage protection for circuits with transient loads, such as EV chargers, workshops, and industrial applications . An RCD monitors residual current and disconnects the circuit when its operating conditions are met. Select the required residual-current type, sensitivity, current rating and pole arrangement.
WCED single-pole 10kA RCBOs combine overload, short-circuit and 30mA residual-current protection. Used for individual circuit protection. Match the current rating, trip curve and pole arrangement to the circuit and approved board specification.
Overload protection of circuits against short-circuit currents and overload currents resulting from defective equipment. An MCB disconnects a circuit in response to an overload or short circuit. Select the current rating, curve and poles required by the circuit design.
100A DIN-rail isolator switch for disconnecting the connected supply. Choose the pole arrangement required by the assembly. Provides a manual means of disconnecting the connected supply for isolation. Select the AC or DC model, poles and current rating to suit the equipment.
DIN-rail modular contactor for switching electrical loads. Select the required current rating, pole arrangement and control voltage. A control signal operates the contacts, allowing equipment such as heating, lighting or charging circuits to be switched remotely.
Overload protection of circuits against short-circuit currents and overload currents resulting from defective equipment. An MCB disconnects a circuit in response to an overload or short circuit. Select the current rating, curve and poles required by the circuit design.
100A DIN-rail isolator switch for disconnecting the connected supply. Choose the pole arrangement required by the assembly. Provides a manual means of disconnecting the connected supply for isolation. Select the AC or DC model, poles and current rating to suit the equipment.
DIN-rail modular contactor for switching electrical loads. Select the required current rating, pole arrangement and control voltage. A control signal operates the contacts, allowing equipment such as heating, lighting or charging circuits to be switched remotely.
WCED 10kA MCBs provide overload and short-circuit protection. An MCB disconnects a circuit in response to an overload or short circuit. Select the current rating, curve and poles required by the circuit design.
2 Module white empty metal enclosure with DIN rail, IP40 for Indoor Application Provides space to house the selected electrical devices. Check enclosure size and the components included with each configuration.
WCED two-pole Type A RCBOs combine residual-current and overcurrent protection. Used for individual circuit protection. Match the current rating, trip curve and pole arrangement to the circuit and approved board specification.
RCBO combining residual-current, overload and short-circuit protection in one device. Used for individual circuit protection. Match the current rating, trip curve and pole arrangement to the circuit and approved board specification.
Overload protection of circuits against short-circuit currents and overload currents resulting from defective equipment. An MCB disconnects a circuit in response to an overload or short circuit. Select the current rating, curve and poles required by the circuit design.
Overload protection of circuits against short-circuit currents and overload currents resulting from defective equipment. An MCB disconnects a circuit in response to an overload or short circuit. Select the current rating, curve and poles required by the circuit design.
Compact 4 pole rotary isolators from the WCED WRS range, from 20A up to 125A for AC, plus 1000V DC versions for solar PV. Provides a manual means of disconnecting the connected supply for isolation. Select the AC or DC model, poles and current rating to suit the equipment.
RCBO combining residual-current, overload and short-circuit protection in one device. Used for individual circuit protection. Match the current rating, trip curve and pole arrangement to the circuit and approved board specification.
Overload protection of circuits against short-circuit currents and overload currents resulting from defective equipment. An MCB disconnects a circuit in response to an overload or short circuit. Select the current rating, curve and poles required by the circuit design.
Overload protection of circuits against short-circuit currents and overload currents resulting from defective equipment. An MCB disconnects a circuit in response to an overload or short circuit. Select the current rating, curve and poles required by the circuit design.
Overload protection of circuits against short-circuit currents and overload currents resulting from defective equipment. An MCB disconnects a circuit in response to an overload or short circuit. Select the current rating, curve and poles required by the circuit design.
Overload protection of circuits against short-circuit currents and overload currents resulting from defective equipment. An MCB disconnects a circuit in response to an overload or short circuit. Select the current rating, curve and poles required by the circuit design.
Overload protection of circuits against short-circuit currents and overload currents resulting from defective equipment. An MCB disconnects a circuit in response to an overload or short circuit. Select the current rating, curve and poles required by the circuit design.
Time Delay RCD's are typically used when two RCD's are installed in series.
Overload protection of circuits against short-circuit currents and overload currents resulting from defective equipment. An MCB disconnects a circuit in response to an overload or short circuit. Select the current rating, curve and poles required by the circuit design.
DIN-rail modular contactor for switching electrical loads. Select the required current rating, pole arrangement and control voltage. A control signal operates the contacts, allowing equipment such as heating, lighting or charging circuits to be switched remotely.
Overload protection of circuits against short-circuit currents and overload currents resulting from defective equipment. An MCB disconnects a circuit in response to an overload or short circuit. Select the current rating, curve and poles required by the circuit design.
DIN-rail modular contactor for switching electrical loads. Select the required current rating, pole arrangement and control voltage. A control signal operates the contacts, allowing equipment such as heating, lighting or charging circuits to be switched remotely.
WCED standalone AC surge protection modules for a specified consumer-unit or distribution-board assembly. An SPD limits transient overvoltages on the AC supply. Choose the device type and connection arrangement specified for the board.
A four-module metal consumer unit for indoor EV charger installations, fitted with a Type A, C-curve RCBO and Type 2 surge protection. A fitted unit brings the listed electrical devices together in one enclosure. Compare the included components and enclosure rating before choosing a variant.
Indoor metal three-phase consumer unit with selectable circuit-protection and surge-protection configurations. A fitted unit brings the listed electrical devices together in one enclosure. Compare the included components and enclosure rating before choosing a variant.
Manual changeover switches from WCED for switching a load between two supplies, such as mains and generator. Used when an installation needs a manual choice between its normal and alternative power source.
WCED single-phase PME/PEN fault protection unit in a plastic IP65 enclosure, with 40A RCBO and selectable surge protection, kWh metering and load-management options. Provides open-PEN fault monitoring within the listed assembly. Use the variant specification to identify the included circuit protection and metering or load-management options.
WCED solar PV combiner boxes bring DC isolation and DC surge protection together in an IP65 enclosure between the array and inverter. Used on the DC side of a solar installation to bring the specified string connections and protection into one assembly.
The WCED WME10-SOL1 is a fitted single-phase solar AC consumer unit with a 20A bi-directional RCBO, 32A rotary isolator and kWh meter. Provides a manual means of disconnecting the connected supply for isolation. Select the AC or DC model, poles and current rating to suit the equipment.
Standalone solar PV DC surge protection modules in 2-pole 600V and 3-pole 1000V configurations. Helps limit transient overvoltages on the solar PV DC circuit. Choose the voltage and pole arrangement from the system specification.
Type B residual-current devices with 2-pole and 4-pole options. Select the current rating and arrangement specified for the installation. An RCD monitors residual current and disconnects the circuit when its operating conditions are met. Select the required residual-current type, sensitivity, current rating and pole arrangement.