Product details & specifications
What this product does
A contactor lets a small control signal switch a separate power circuit. A timer, thermostat or controller energises its coil; the contacts then change state to control the connected load.
When to use it
Use a contactor when equipment needs automatic or remote on/off control. For example, a timer can operate the coil while the contactor switches a lighting or heating circuit. Match the contact duty to the actual load and its starting current.
What is included
- One modular contactor in the selected pole, contact-current and coil specification.
- Controller, enclosure and circuit protection are supplied separately.
Choosing your options
Poles are separate switched paths. Normally open (NO) contacts close when the coil is energised; normally closed (NC) contacts open. “Normal” means the coil has no power. The coil voltage operates the device; the amp rating applies to its contacts under the specified load duty. AC means alternating current and DC means direct current. This listing includes 240V AC-labelled and 24V DC-labelled coil options. 12V describes a voltage, not AC or DC; no 12V coil option is listed. The /1M 32A version is a distinct narrow model.
What it does not replace
A contactor is a switching device, not a circuit breaker. It does not replace overload, residual-current, surge or open-PEN protection. A DC coil rating does not establish that the contacts can switch a DC load.
Specifications and dimensions
Use the selected configuration above for its part code and current price. Match the exact device and enclosure to the manufacturer’s technical information, allowing cable-entry and wiring clearance as well as the product dimensions.
Product dimensions in millimetres: width × height × depth. Match the part code to your selected variant. Allow additional installation and cable clearance.
| Part code / variant | W × H × D (mm) |
|---|---|
|
WAC2P20 2 poles / Normally open (NO) – 240V AC / 20A |
18 × 84 × 68 |
|
WAC2P25 2 poles / Normally open (NO) – 240V AC / 25A |
18 × 84 × 68 |
|
WAC2P32 2 poles / Normally open (NO) – 240V AC / 32A |
36 × 84 × 68 |
|
WAC2P40 2 poles / Normally open (NO) – 240V AC / 40A |
36 × 84 × 68 |
|
WAC2P63 2 poles / Normally open (NO) – 240V AC / 63A |
36 × 84 × 68 |
|
WAC4P20 4 poles / Normally open (NO) – 240V AC / 20A |
36 × 84 × 68 |
|
WAC4P25 4 poles / Normally open (NO) – 240V AC / 25A |
36 × 84 × 68 |
|
WAC4P32 4 poles / Normally open (NO) – 240V AC / 32A |
54 × 84 × 68 |
|
WAC4P40 4 poles / Normally open (NO) – 240V AC / 40A |
54 × 84 × 68 |
This table covers the exact standard-coil models listed. Dimensions for 100A/125A, low-voltage, NC, mixed-contact and /1M versions require separate confirmation.
Manufacturer range and technical information
Common questions
What does the coil voltage mean?
It must match the control supply. For example, a 24V DC coil needs the specified 24V DC control supply. The voltage of the circuit being switched is a separate rating.
What do the CO options do?
On this WCED range, the CO models have mixed NO and NC contacts: WAC2P20CO has one of each; WAC4P25CO has two of each. Use the terminal diagram. These are not automatically suitable for transferring a load between two power sources.
Delivery and help choosing
WCED standard delivery is £10, normally 1–2 working days. Express delivery is £20, normally next working day. WCED products are excluded from free delivery.
Ask us to help identify the right part — send the part code or equipment model and the specification you need.