WCED Heat Pump Consumer Units & Type B RCDs

WCED • Electrical protection & switching

WCED Heat Pump Consumer Units & Type B RCDs

Compare fitted WCED heat-pump protection units and standalone Type B RCDs. Begin with the heat-pump manufacturer's electrical specification, then choose the device or assembly that matches the supply and protection requirements.

Find the right product

Open a product to select its exact configuration and see current prices and availability.

Heat Pump Protection Consumer Unit – Type B RCD + Surge + 2‑Pole MCB

Fitted heat-pump protection

Explore the consumer-unit range combining Type B RCD, MCB and surge protection.

View options & prices →
Heat Pump Protection Consumer Unit 20khz Type B

20kHz Type B option

Compare this separately listed range where its specified RCD characteristics are required.

View options & prices →
WCED Type B RCD | 2 & 4 Pole, 25–63A, 30mA | EcoHarmony

Standalone Type B RCD

Choose a separate device when the panel design calls for an individual RCD rather than a fitted assembly.

View options & prices →

Before you choose

1

Start with the equipment manual

Record the heat-pump model, supply phase, circuit rating and the required RCD characteristics. Do not assume every heat pump needs the same device.

2

Choose the assembly

Compare a fitted consumer unit with an individual RCD. Check the exact MCB, SPD and enclosure supplied in the selected option.

3

Confirm the installation

Check coordination with upstream protection, cable design, mounting environment and the manufacturer's installation instructions.

Planning an enclosure and components?

Our consumer-unit builder lets you choose single-phase or three-phase, select an enclosure and track the spare DIN space as you add supported components. Custom selections are supplied separately; factory-configured units have their own stated contents.

Build your own consumer unit →

Frequently asked questions

Does every heat pump need a Type B RCD?

No universal selection applies to every model. Follow the equipment manufacturer's specified residual-current protection and the installation design.

Is a Type B RCD the same as a B-curve MCB?

No. Type B describes residual-current detection characteristics. B curve describes an MCB's instantaneous overcurrent trip characteristic.

Does an RCD also protect against overload?

An RCD alone does not provide overload or short-circuit protection. A suitable overcurrent protective device is also needed as part of the design.

Can I order protection without a complete consumer unit?

Yes. The standalone Type B RCD range is linked here. Check that the chosen device is compatible with the intended assembly.

From our knowledge base

Get more detail before choosing a configuration.

Explore related WCED ranges

Product selection guidance from EcoHarmony. Check the exact product datasheet and manufacturer instructions for the chosen configuration.

Explore Our Guides

A different set of guides each time you visit — covering troubleshooting, buying advice, technical explainers, and more.