The RCM14-01 is a residual current monitor intended for the detection of DC residual currents at 6mA or greater in 50Hz/60Hz AC installations. The RCM14-01 is primarily intended for use in Mode 3 Electric Vehicle charging stations to disconnect the supply to the Electric Vehicle under a DC residual fault current condition. The RCM14-01 may also be used to detect DC residual currents in DC, single phase or multiphase installations. The RCM14-01 is a compact solution designed to be panel mounted. It has a JST connector for easy installation. This product is fully compliant with IEC62955.
• Complies with the DC protection requirements of IEC62955 (Mode 3)
• 3000A Surge Current Withstand
• 14mm Aperture
Supply Conditions
The RCM14-01 is intended for operation with a supply voltage of 12V DC +/- 10%. Performance may be compromised if the supply voltage is outside these limits.
Fault Operation & Auto Reset
When a residual fault current that exceeds the rated DC level is detected, the RCM14-01 Output pin will switch to the “Fault” state within the specified response times. The Output pin will Auto-Reset when the fault is removed.
(Cable assembly available also).
Pin 1: 0V DC
Pin 2: +12V DC
Pin 3: External Test Facility
Pin 4: Fault Signal Output (Active High Open Drain)