{"product_id":"war-series-time-delay-type-a-rcds-100-ma-1","title":"WAR Series A‑Type B‑Curve 30 mA Single-Module AFDD\/RCBO","description":"\u003ctitle\u003eWCED WFD Series – A-Type AFDD RCBO | Arc Fault Detection | EcoHarmony\u003c\/title\u003e\n\u003cmeta name=\"description\" content=\"WCED WFD Series single-module AFDD RCBO. Arc fault detection, 30mA Type A RCD and B-curve MCB in one device. BS EN 62606 compliant. Mandatory for HMOs and care homes. 6A–40A available.\"\u003e\n\n\u003cstyle\u003e\n.eh-container {max-width:1100px;margin:auto;padding:60px 20px;font-family:-apple-system,BlinkMacSystemFont,sans-serif;}\n\n.eh-highlight {\n  background:#ecfdf5;\n  border-left:5px solid #10b981;\n  padding:20px;\n  border-radius:10px;\n  margin-bottom:25px;\n  font-size:18px;\n}\n\n.eh-text {\n  margin:20px 0;\n  line-height:1.7;\n  color:#374151;\n}\n\n.eh-icon-list {\n  display:grid;\n  grid-template-columns:repeat(auto-fit,minmax(200px,1fr));\n  gap:15px;\n  margin:25px 0;\n}\n\n.eh-icon {\n  background:#f9fafb;\n  padding:15px;\n  border-radius:12px;\n  font-weight:500;\n}\n\n.eh-icon::before {\n  content:\"✔\";\n  color:#10b981;\n  margin-right:8px;\n}\n\n.eh-cta-box {\n  background:#ecfdf5;\n  border:2px solid #10b981;\n  padding:25px;\n  border-radius:16px;\n  margin:40px 0;\n}\n\n.eh-cta-box a {\n  display:inline-block;\n  margin-top:10px;\n  background:#10b981;\n  color:#fff;\n  padding:12px 18px;\n  border-radius:10px;\n  text-decoration:none;\n  font-weight:600;\n}\n\n.eh-cards {\n  display:grid;\n  grid-template-columns:repeat(auto-fit,minmax(260px,1fr));\n  gap:20px;\n  margin:30px 0;\n}\n\n.eh-card {\n  border:1px solid #e5e7eb;\n  border-radius:16px;\n  padding:20px;\n  background:#fff;\n  transition:.3s;\n  box-shadow:0 4px 10px rgba(0,0,0,0.04);\n}\n\n.eh-card:hover {\n  transform:translateY(-6px);\n  box-shadow:0 12px 25px rgba(0,0,0,0.08);\n}\n\n.eh-card h3 {margin:0 0 8px 0;font-size:16px;}\n.eh-card p {margin:0 0 10px 0;color:#374151;font-size:14px;line-height:1.6;}\n.eh-card a {display:inline-block;color:#10b981;font-weight:600;text-decoration:none;}\n\n.eh-table {\n  width:100%;\n  border-collapse:collapse;\n  margin:30px 0;\n}\n\n.eh-table th {\n  background:#111827;\n  color:#fff;\n  padding:12px;\n}\n\n.eh-table td {\n  padding:12px;\n  border-bottom:1px solid #e5e7eb;\n}\n\n.eh-table tr:last-child td {border-bottom:none;}\n\n.eh-faq-item {\n  border:1px solid #e5e7eb;\n  border-radius:12px;\n  padding:15px;\n  margin-bottom:12px;\n  background:#fff;\n}\n\n.eh-faq-item h3 {\n  margin:0 0 8px 0;\n  font-size:16px;\n}\n\n.eh-faq-item p {\n  margin:0;\n  color:#374151;\n  line-height:1.6;\n}\n\n.eh-faq-item ul {\n  color:#374151;\n  line-height:1.8;\n  margin:8px 0 0 0;\n  padding-left:20px;\n}\n\n.eh-sticky {\n  position:fixed;\n  bottom:0;\n  width:100%;\n  background:#111827;\n  color:#fff;\n  padding:12px 20px;\n  display:flex;\n  justify-content:space-between;\n  align-items:center;\n  z-index:999;\n}\n\n.eh-sticky a {\n  background:#10b981;\n  padding:10px 15px;\n  border-radius:8px;\n  color:#fff;\n  text-decoration:none;\n  font-weight:600;\n}\n\u003c\/style\u003e\n\n\u003csection class=\"eh-container\"\u003e\n\n\u003ch1\u003eWCED WFD Series – A-Type AFDD RCBO\u003c\/h1\u003e\n\n\u003cdiv class=\"eh-highlight\"\u003e\n\u003cstrong\u003eArc fault detection, 30 mA residual current protection, and B-curve overload protection — in one single module.\u003c\/strong\u003e The WFD Series is a direct drop-in replacement for any standard single-module RCBO, with no consumer unit change required.\n\u003c\/div\u003e\n\n\u003cdiv class=\"eh-text\"\u003e\n\u003cp\u003eThe WAR Series A-Type B-Curve 30 mA AFDD modules provide arc fault, overload, and residual current protection in a single compact module. Designed for residential, commercial, and light industrial applications, these units help prevent electrical fires caused by arc faults while protecting circuits with B-curve overcurrent characteristics.\u003c\/p\u003e\n\n\u003cp\u003eDIN-rail mountable and fully compliant with UK wiring regulations and BS EN 62606, these devices are ideal for circuits where enhanced fire detection and leakage protection is required. High-spec, installer-friendly AFDD modules with compact single-module design.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\n\u003cdiv class=\"eh-icon-list\"\u003e\n  \u003cdiv class=\"eh-icon\"\u003eArc Fault Detection (AFDD) + MCB + RCD in one\u003c\/div\u003e\n  \u003cdiv class=\"eh-icon\"\u003eA-Type detection — AC and pulsating DC\u003c\/div\u003e\n  \u003cdiv class=\"eh-icon\"\u003eB-Curve — general-purpose overload protection\u003c\/div\u003e\n  \u003cdiv class=\"eh-icon\"\u003e30 mA sensitivity — fire and shock protection\u003c\/div\u003e\n  \u003cdiv class=\"eh-icon\"\u003eSingle-module width (17.8 mm)\u003c\/div\u003e\n  \u003cdiv class=\"eh-icon\"\u003eBS EN 62606 and UKCA compliant\u003c\/div\u003e\n  \u003cdiv class=\"eh-icon\"\u003eSuitable for EV charging circuits\u003c\/div\u003e\n  \u003cdiv class=\"eh-icon\"\u003eDrop-in retrofit — no board change needed\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\n\u003cdiv class=\"eh-cards\"\u003e\n  \u003cdiv class=\"eh-card\"\u003e\n    \u003ch3\u003eHMOs and rental properties\u003c\/h3\u003e\n    \u003cp\u003eMandatory under BS 7671 Amendment 2 (March 2022) for socket circuits ≤32A in Houses in Multiple Occupation, care homes, and purpose-built student accommodation.\u003c\/p\u003e\n    \u003ca href=\"\/collections\/wced-products\"\u003eView WCED range →\u003c\/a\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"eh-card\"\u003e\n    \u003ch3\u003eResidential and commercial circuits\u003c\/h3\u003e\n    \u003cp\u003eSuitable for all standard final circuits in new builds, consumer unit upgrades, and rewire projects where enhanced fire protection is required or specified.\u003c\/p\u003e\n    \u003ca href=\"\/collections\/single-phase-distribution-boards\"\u003eView distribution boards →\u003c\/a\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"eh-card\"\u003e\n    \u003ch3\u003eEV charging circuits\u003c\/h3\u003e\n    \u003cp\u003eProvides arc fault protection on EV supply circuits — particularly useful for garage and outbuilding installations where cable routing creates higher arc risk.\u003c\/p\u003e\n    \u003ca href=\"\/collections\/wced-products\"\u003eView EV protection →\u003c\/a\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"eh-card\"\u003e\n    \u003ch3\u003eWorkshops and light industrial\u003c\/h3\u003e\n    \u003cp\u003eFor workshops, commercial units, and light industrial premises where wiring is subject to mechanical damage, aging, or higher arc fault risk.\u003c\/p\u003e\n    \u003ca href=\"\/collections\/wced-products\"\u003eView WCED range →\u003c\/a\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003ch2\u003eHow it works\u003c\/h2\u003e\n\n\u003cdiv class=\"eh-text\"\u003e\n\u003cp\u003eA standard RCBO protects against overloads, short circuits, and earth leakage. The WCED WFD Series adds a fourth layer: continuous waveform monitoring using an integrated microprocessor that analyses the current signature on the circuit and detects the characteristic patterns of dangerous electrical arcing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ctable class=\"eh-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eFault type\u003c\/th\u003e\n\u003cth\u003eCause\u003c\/th\u003e\n\u003cth\u003eDetected by MCB\/RCD alone?\u003c\/th\u003e\n\u003cth\u003eDetected by AFDD RCBO?\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries arc fault\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoose terminal, broken conductor, rodent damage\u003c\/td\u003e\n\u003ctd\u003e❌ No\u003c\/td\u003e\n\u003ctd\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParallel arc fault\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDamaged insulation, pinched or crushed cable\u003c\/td\u003e\n\u003ctd\u003e⚠️ Only if current exceeds trip threshold\u003c\/td\u003e\n\u003ctd\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarth leakage (30 mA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFaulty equipment, wiring fault to earth\u003c\/td\u003e\n\u003ctd\u003e✅ Yes (RCBO\/RCD)\u003c\/td\u003e\n\u003ctd\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \/ short circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExcess current draw, dead short\u003c\/td\u003e\n\u003ctd\u003e✅ Yes (MCB\/RCBO)\u003c\/td\u003e\n\u003ctd\u003e✅ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable class=\"eh-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e6A, 10A, 16A, 20A, 32A, 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip curve\u003c\/th\u003e\n\u003ctd\u003eB Curve (3–5× In)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRCD type\u003c\/th\u003e\n\u003ctd\u003eType A — AC and pulsating DC (up to 6 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRCD sensitivity\u003c\/th\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd\u003e6 kA (Icn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e1P+N (switched — Line and Neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule width\u003c\/th\u003e\n\u003ctd\u003e17.8 mm (1 module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e90 × 17.8 × 77 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003ctd\u003eIP20 — indoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e230V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eArc detection\u003c\/th\u003e\n\u003ctd\u003eSeries and parallel arc faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSelf-test\u003c\/th\u003e\n\u003ctd\u003eAutomatic periodic self-test per BS EN 62606\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFault indicator\u003c\/th\u003e\n\u003ctd\u003eLED blink-code diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003eBS EN 62606, IEC 61009-1, BS 7671:2018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompliance\u003c\/th\u003e\n\u003ctd\u003eUKCA marked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eWCED (Whitecliffe Electrical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\u003ch2\u003ePart numbers\u003c\/h2\u003e\n\n\u003ctable class=\"eh-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003ePart code\u003c\/th\u003e\n\u003cth\u003eRating\u003c\/th\u003e\n\u003cth\u003eCurve\u003c\/th\u003e\n\u003cth\u003eRCD type\u003c\/th\u003e\n\u003cth\u003eTypical application\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:monospace;color:#1d4ed8;font-weight:600;\"\u003eWFD106B-030\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eType A 30mA\u003c\/td\u003e\n\u003ctd\u003eLighting circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:monospace;color:#1d4ed8;font-weight:600;\"\u003eWFD110B-030\u003c\/td\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eType A 30mA\u003c\/td\u003e\n\u003ctd\u003eLow-load lighting circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0fdf4;\"\u003e\n\u003ctd style=\"font-family:monospace;color:#1d4ed8;font-weight:600;\"\u003eWFD116B-030\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eType A 30mA\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRing and radial socket circuits — most common\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:monospace;color:#1d4ed8;font-weight:600;\"\u003eWFD120B-030\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eType A 30mA\u003c\/td\u003e\n\u003ctd\u003eDedicated appliance circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0fdf4;\"\u003e\n\u003ctd style=\"font-family:monospace;color:#1d4ed8;font-weight:600;\"\u003eWFD132B-030\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e32A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eType A 30mA\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRing mains, EV charging, cookers\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-family:monospace;color:#1d4ed8;font-weight:600;\"\u003eWFD140B-030\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eType A 30mA\u003c\/td\u003e\n\u003ctd\u003eHigh-load and shower circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\n\u003cdiv class=\"eh-text\"\u003e\n\u003cp\u003e\u003cstrong\u003eIndoor use only (IP20).\u003c\/strong\u003e DIN-rail mountable — fits any standard consumer unit or distribution board that accepts a single-module RCBO. Must be installed by a qualified electrician. Ensure the correct current rating is selected for each individual circuit. The flying neutral cable can be cut to suit installation depth. The Line and Neutral conductors do not need to be disconnected for IR testing when the lever is in the OFF position.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003cdiv class=\"eh-faq-item\"\u003e\n\u003ch3\u003eWhat is an AFDD and what does it protect against?\u003c\/h3\u003e\n\u003cp\u003eAn AFDD (Arc Fault Detection Device) detects dangerous electrical arcing caused by loose connections, damaged cable insulation, or crushed wires — faults that generate intense heat and can cause fires without tripping a standard MCB or RCD. The WFD Series adds arc fault detection on top of a full RCBO, giving four layers of protection in a single module.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"eh-faq-item\"\u003e\n\u003ch3\u003eWhat is the difference between the Plus Tethered and Basic Tethered?\u003c\/h3\u003e\n\u003cp\u003eBoth have a permanently attached 6.8 or 9.6 m Type 2 cable. The Plus adds solar charging compatibility, built-in energy monitoring, and dynamic load management via the Wireless Energy Manager. If you have solar panels, choose the Plus.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"eh-faq-item\"\u003e\n\u003ch3\u003eAre AFDDs mandatory in the UK?\u003c\/h3\u003e\n\u003cp\u003eSince March 2022, AFDDs are mandatory under BS 7671:2018 Amendment 2 for socket circuits rated ≤32A in the following building types:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHouses in Multiple Occupation (HMOs)\u003c\/li\u003e\n  \u003cli\u003eHigher Risk Residential Buildings (HRRBs) — over 18m or 6+ storeys\u003c\/li\u003e\n  \u003cli\u003ePurpose-built student accommodation\u003c\/li\u003e\n  \u003cli\u003eCare homes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThey are strongly recommended for all other domestic and commercial installations as fire-risk best practice.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"eh-faq-item\"\u003e\n\u003ch3\u003eWill this fit in my existing consumer unit?\u003c\/h3\u003e\n\u003cp\u003eYes. The WFD Series is 17.8 mm wide (one module) and is a direct drop-in replacement for any single-module RCBO in a standard consumer unit. No board change required. Compatible with all standard DIN-rail consumer units.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"eh-faq-item\"\u003e\n\u003ch3\u003eWhat is the difference between a Type A and Type B AFDD RCBO?\u003c\/h3\u003e\n\u003cp\u003eType A (WFD Series) detects AC residual currents and pulsating DC up to 6 mA — suitable for the majority of domestic circuits and most EV chargers. Type B additionally detects smooth DC residual currents and is required for some 3-phase EV chargers. For most residential and commercial final circuits, Type A is the correct specification.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"eh-faq-item\"\u003e\n\u003ch3\u003eWhat is a B-curve and when should I use it?\u003c\/h3\u003e\n\u003cp\u003eB-curve MCBs trip at 3–5× the rated current. They are the correct choice for resistive loads — lighting circuits, socket circuits, and general domestic wiring. C-curve devices (5–10×) are used for inductive loads with high start-up currents such as motors and compressors. B-curve is correct for the vast majority of residential and commercial final circuits.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"eh-faq-item\"\u003e\n\u003ch3\u003eCan an AFDD cause nuisance tripping?\u003c\/h3\u003e\n\u003cp\u003eThe WFD Series uses high-immunity filtering to distinguish genuine arc fault signatures from normal equipment switching and load noise. Nuisance tripping is uncommon in correctly installed circuits. The LED blink-code indicator on the device identifies the cause of any trip, making fault diagnosis straightforward.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"eh-faq-item\"\u003e\n\u003ch3\u003eHow do I test the device after installation?\u003c\/h3\u003e\n\u003cp\u003ePress the integral test button with the circuit energised — the device should trip immediately. Reset by switching the lever to ON. The arc fault detection element performs automatic periodic self-tests internally to BS EN 62606. No additional test tool is required for routine testing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"eh-faq-item\"\u003e\n\u003ch3\u003eIs this suitable for EV charging circuits?\u003c\/h3\u003e\n\u003cp\u003eYes — the WFD Series is suitable for EV supply circuits where Type A RCD protection is specified. For EV chargers that explicitly require Type B RCD protection (typically 3-phase units without integrated DC protection), a Type B RCBO or RCD should be used instead. Check your charger manufacturer's documentation for the required RCD type.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\n\u003c\/section\u003e\n\n\u003cdiv class=\"eh-sticky\"\u003e\n\u003cspan\u003eWCED WFD Series — AFDD RCBO, 6A–40A\u003c\/span\u003e\n\u003ca href=\"\/collections\/other-wced-products-accessories-modules-extras\"\u003eShop now\u003c\/a\u003e\n\u003c\/div\u003e\n\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\"@type\": \"ListItem\", \"position\": 1, \"name\": \"Home\", \"item\": \"https:\/\/ecoharmony.co.uk\"},\n    {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"Electrical Protection \u0026 Distribution\", \"item\": \"https:\/\/ecoharmony.co.uk\/collections\/wced-products\"},\n    {\"@type\": \"ListItem\", \"position\": 3, \"name\": \"WCED WFD Series AFDD RCBO\", \"item\": \"https:\/\/ecoharmony.co.uk\/collections\/other-wced-products-accessories-modules-extras\"}\n  ]\n}\n\u003c\/script\u003e","brand":"WCED","offers":[{"title":"6","offer_id":57128523006339,"sku":"WFD106B-030","price":74.99,"currency_code":"GBP","in_stock":true},{"title":"10","offer_id":57128523039107,"sku":"WFD110B‑030","price":74.99,"currency_code":"GBP","in_stock":true},{"title":"16","offer_id":57128523071875,"sku":"WFD116B‑030","price":79.99,"currency_code":"GBP","in_stock":true},{"title":"20","offer_id":57128530903427,"sku":"WFD120B‑030","price":79.99,"currency_code":"GBP","in_stock":true},{"title":"32","offer_id":57128530936195,"sku":"WFD132B‑030","price":84.99,"currency_code":"GBP","in_stock":true},{"title":"40","offer_id":57128530968963,"sku":"WFD140B‑030","price":84.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1033\/7545\/files\/WFD132C-030-492x1024.png?v=1767470633","url":"https:\/\/ecoharmony.co.uk\/products\/war-series-time-delay-type-a-rcds-100-ma-1","provider":"EcoHarmony","version":"1.0","type":"link"}